| Class |
Capacitance Range |
Voltage Range |
Insulation Resistance |
Dissipation Factor (Max %) |
Test Frequency |
Breakdown Voltage |
| General Purpose |
1 pF to 100,000 pF |
50, 100, 500, 1000 VDC |
10,000 megohms (min) |
Z5U: 4.0 Y5U: 4.0 Y5V: 5.0% All Others:
2.5 |
1,000 Hz |
2.5 x rated (5 seconds Max) |
EIA Class 1 Temp
Compensating |
1 pF to 910 pF |
50, 500, 1000, 3000 VDC |
10,000 megohms (min) |
5.0 |
1 MHz |
3 x rated (5 seconds Max) |
EIA Class
2 Temp/Frequency Stable |
100 pF to 10,000 pF |
500 and 1000 VDC |
10,000 megohms (min) |
1.5 |
1,000 Hz |
2.5 x rated (5 seconds Max) |
EIA Class 2 High
Voltage |
100 pF to 10,000 pF |
2000 and 3000 VDC |
10,000 megohms (min) |
2.5 |
1,000 Hz |
2.5 x rated (5 seconds Max) |
EIA Class
3 Reduced Titanite High Capacitance |
0.01 µF to 0.22 µF |
12, 25, 50 VDC |
1 megohm (min) |
Y5R: 1.5 Y5U: 7.0 Y5V: 5.0% |
1,000 Hz (Operating) |
2.5 x rated (5 seconds Max) |
| Spark-Arrestor |
.75 pF Max(gap only) to .01 µF |
1 - 3 KVDC |
n/a |
n/a |
n/a |
n/a |
X Type U.L., CSA
& VDE Recognized Across-The-Line |
0.001 µF to 0.01 µF |
125 Vrms 60 Hz |
>10K megohms @25°C, 500 VDC |
2.5 |
1,000 Hz |
3,250 min Vrms, 60Hz (1 minute
Max) |
X1 - Y1
Type Across-The-Line |
100 pF to 0.01 µF |
250 Vrms 60 Hz |
-- |
2.0 |
-- |
4,000 min Vrms |
|