Detailed Specifications For Series U32D
• Large Can
Screw Terminal
High Ripple Current Capability
Extended Temperature Range to +105°C
Dimensions in Inches

The U32D series allows for extremely high ripple currents for applications such as inverter designs and motor controllers. The extended temperature range allows for a high operating temperature without sacrificing life. All dimensions are based on the original 36D case sizes which are in inches. A stud mount can is available upon request.
Item Characteristics
Operating Temperature Range -40 to +105°C
Rated Voltage Range 6.3 to 400VDC
Capacitance Range 180µF to 2.2F at +25°C, 120Hz
Capacitance Tolerance ±20% (M) at +25°C, 120Hz
Leakage Current I = 0.02CV (µA) or 5µA, whichever is smaller, after 5 minutes at +25°C.

Where I = Leakage current (µA), C = Nominal capacitance (µF) and V = Rated voltage (V)

Ripple Current Multipliers

Refer to Section 4 of the Mini-Glossary for explanation of Ripple Current Multipliers.

Ambient Temperature (°C)
<=+45°C +65°C +85°C +105°C
1.41 1.29 1 0.57

Frequency (Hz)
DC Rated Voltage Case Diameter 50Hz 120Hz 300Hz 1kHz 10kHz 50kHz
10-50V 035-076 0.95 1 1.03 1.05 1.09 1.12
63-80V 035 0.9 1 1.06 1.1 1.18 1.22
63-80V 051-076 0.95 1 1.03 1.05 1.09 1.12
100V 035 0.82 1 1.12 1.22 1.3 1.33
100V 051 0.9 1 1.06 1.1 1.18 1.22
100V 063-076 0.95 1 1.03 1.05 1.09 1.12
160-250V 035 0.8 1 1.19 1.34 1.46 1.52
160-250V 051-063 0.81 1 1.14 1.26 1.36 1.41
160-250V 076 0.82 1 1.12 1.22 1.3 1.33
315-400V 035-076 0.8 1 1.19 1.34 1.46 1.52

Life Validation Test The following specifications shall be satisfied when the capacitors are restored to +25°C after subjecting them to the DC rated voltage for 2,000 hours at +105°C with the rated ripple current applied.

Capacitance change : <= 20% from initial measurement
ESR change : <= 200% of initial specified limit Leakage current : <= initial specified limit

Shelf Test The following specifications shall be satisfied when the capacitors are restored to +25°C after exposing them for 500 hours at +105°C without voltage applied. The rated voltage shall be applied to the capacitors for a minimum of 30 minutes, at least 24 hours and not more than 48 hours before the measurements.

Capacitance change : <= 20% from initial measurement
ESR change : <= 200% of initial specified limit
Leakage current : <= initial specified limit