| Item |
Characteristics |
| Operating Temperature Range |
-55 to +105°C |
| Rated Voltage Range |
6.3 to 50VDC |
| Capacitance Range |
0.1 to 10,000µF |
| Capacitance Tolerance |
±20% (M) at +20°C, 120Hz |
| Leakage Current |
I = 0.01CV or 3µA, whichever is greater, after 2 minutes at +20°C.
Where I = Leakage current (µA), C = Nominal capacitance (µF) and V =
Rated voltage (V) |
| Dissipation Factor (Tan d) |
At +20°C, 120Hz
| Rated Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
| Tan d (DF) |
0.24 |
0.2 |
0.16 |
0.14 |
0.12 |
0.1 | |
| Low Temperature Characteristics |
At 120Hz, impedance (Z) ratio between the -25°C or -40°C value and
+20°C value shall not exceed the values given below.
| Rated Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
| Z (-25°C)/Z (+20°C) |
5 |
4 |
3 |
2 |
2 |
2 |
| Z (-40°C)/Z (+20°C) |
10 |
8 |
6 |
4 |
3 |
3 | |
| Ripple Current Multipliers
Refer to Section 4 of the Mini-Glossary for explanation of Ripple
Current Multipliers. |
Ambient Temperature (°C)
Frequency (Hz)
| Capacitance (µF) |
50Hz |
120Hz |
300Hz |
1kHz |
10kHz |
100kHz |
| <= 3.3µF |
0.65 |
1 |
1.35 |
1.75 |
2.3 |
2.5 |
| 4.7-33µF |
0.75 |
1 |
1.25 |
1.5 |
1.75 |
1.8 |
| 47-1000µF |
0.8 |
1 |
1.15 |
1.3 |
1.4 |
1.5 |
| >= 2200µF |
0.85 |
1 |
1.03 |
1.05 |
1.08 |
1.08 | |
| Load Life |
The following specifications shall be satisfied when the capacitors
are restored to +20°C after subjecting them to the DC rated voltage for
1,000 hours at +105°C. The sum of DC voltage and peak AC voltage must not
exceed the full rated voltage of the capacitors.
Capacitance change : <= ±25% of initial measured value for <=
16V : <= ±20% of initial measured value for >= 25V Tan d (DF)
: <= 200% of initial specified value Leakage current : <= initial
specified value |
| Shelf Life |
The following specifications shall be satisfied when the capacitors
are restored to +20°C after exposing them for 500 hours at +105°C without
voltage applied. The rated voltage shall be applied to the capacitors for
a minimum of 30 minutes, at least 24 hours and not more than 48 hours
before the measurements.
Capacitance change : <= ±25% of initial measured value for <=
16V : <= ±20% of initial measured value for >= 25V Tan d (DF)
: <= 200% of initial specified value Leakage current : <= initial
specified value |
| Others |
Satisfies characteristic W of JIS C5141 |